nc building code wall framing

A dedicated space directly over a panelboard that extends from the panelboard to the ceiling shall be kept clear of unrelated equipment. See also: What Happens if You Get Caught Remodeling without a Permit? Do not apply more than the recommended amount of storage in the miscellaneous category to meet the total. Toilets: Shall be water-conserving low consumption at 1.6 gallons per flush and shall be provided with a flush tank or similar device designed and installed to supply water in sufficient quantity and flow to flush the contents of the fixture, to cleanse the fixture and refill the fixture trap. You will find information concerning footings, foundations, framing for floors, walls, ceilings and rafters to help you create the perfect screen porch. Every bedroom shall have at least one operable window or exterior door approved for emergency egress or rescue. 16 ounces per square foot for cold-rolled copper and lead-coated copper, 12 ounces per square foot for copper shingles, high-yield copper and lead-coated high-yield copper. Documents The furnace room shall have an opening or door large enough to permit removal of the largest piece of equipment, but not less than 20 inches wide. NKBA's solution is the combined landing zone. We are not affiliated with, and do not receive any compensation from, any of the companies or products mentioned in this blog. The effect of this rule is to prevent the refrigerator or stove being installed along the same wall as the sink. Range hood may be cord-and-plug (not hard-wired) if the receptacle it plugs into is on its own circuit. But if it drains slowly and is prone to clogs, chances are it's not up to code and should get an upgrade. Vent hoods rated for more than 400 cubic feet per minute (cfm) require make-up air (fresh-air intake in an approved area of the home). Include at least 15 inches of landing area on the handle side of the refrigerator. Studs in non-loadbearing walls may be notched to a depth not to exceed 40 percent of a single stud width. Contact the appropriate agencies such as the Fire Department, Municipality, Sewer District, Subdivision Trustees, etc. You guessed it! Minimum clearance in front of cleanouts shall be 18 inches on 3 inches and larger pipes, and 12 inches on smaller pipes. For 36-inch high counters, a minimum 15-inch deep clear knee space for each seated diner. Find finished basement contractors near me. See also: 5 of the Most Durable Kitchen Materials. Installation of the EIFS and EIFS with drainage shall be in accordance with the EIFS manufacturer's instructions. Retaining walls shall be designed for the lateral soil loads set forth in Section 1610. Switch must be placed at the entrance. R402.1.2 - Wood Frame Wall R-15 or R-13 + 2.5 ci R-15 or R-13 + 2.5 ci R-19 or R-13 + 5 ci or R-15 + 3 ci Clothes washers: The discharge of a clothes washer shall be through an air break. For safety reasons, in an island or peninsula situation, the countertop should also extend a minimum of 9 inches, At least 30 inches of clearance is required between the cooking surface and an unprotected/combustible surface above it. There are no specific IRC microwave placement guidelines. The code is made up by modifications to the International Codes. The Residential Code is on a 6-year adoption cycle by statute. Fiber-cement siding shall conform to the requirements of ASTM C1186, Type A (or ISO 8336, Category A), and shall be so identified on labeling listing an, Class I vapor retarders shall not be provided on the interior side of frame, Class III vapor retarders shall be permitted where any one of the conditions in Table 1405.3.2 is met. 11, deleted from 1/1/2002 through 12/31/2009 while NC had a certified accessibility code, became enforceable on 1/1/2010. Guards along open-sided stairs shall be a minimum of 34" in height above the leading edge of the tread and minimum of 36" in height at the stair landings. Buying a home in North/Central Florida? Contact Customer Service 980-314-CODE (2633) Send an Email To be comfortable while you're seated, you need plenty of knee and elbow room. Proper lighting is essential in a kitchen. GFCI outlets are required in damp environments like kitchens to help prevent shock by instantly depowering if they detect a fault. Kitchen seating should be a minimum of 24-inch wide for each person and: For 30-inch high tables/counters, a minimum 18-inch deep clear knee space for each seated diner. A strainer, crossbar or other device shall be provided to restrict the clear opening of the waste outlet. We will get it done for you. Ducts must be metal and have a smooth interior, with the exception of ducts for downdraft vents that run under concrete slabs: these may be PVC. McGarry and Madsen's home inspection blog for buyers of, site-built, mobile/manfuactured and modular homes. The 2011 Electrical Code was effective from July 3, 2011 through April 1, 2016. 1403.5 Vertical and Lateral Flame Propagation, [BS] 1403.7 Flood Resistance for Coastal High-Hazard Areas and Coastal A Zones, 1404.11 Exterior Insulation and Finish Systems, Section 1405 Installation of Wall Coverings, For SI: 1 inch = 25.4 mm, 1 ounce = 28.35 g, 1 square foot = 0.093 m, 1405.3.4 Minimum Clear Airspaces and Vented Openings for Vented Cladding, [BS] 1405.10.1 Exterior Adhered Masonry Veneer, [BS] 1405.10.1.1 Water-Resistive Barriers, [BS] 1405.10.1.2.1 Flashing at Foundation, [BS] 1405.10.1.4 Adhered Masonry Veneer Installed With Lath and Mortar, [BS] 1405.10.1.5 Adhered Masonry Veneer Applied Directly to Masonry and Concrete, [BS] 1405.10.1.6 Cold Weather Construction, [BS] 1405.10.1.7 Hot Weather Construction, [BS] 1405.10.2 Exterior Adhered Masonry VeneersPorcelain Tile, [BS] 1405.10.3 Interior Adhered Masonry Veneers, [BS] 1405.12.4 Installation at Sidewalk Level, [BS] 1405.12.4.1 Installation Above Sidewalk Level, Section 1406 Combustible Materials on the Exterior Side of Exterior Walls, 1406.2 Combustible Exterior Wall Coverings, 1406.2.1 Type I, II, III and IV Construction, 1406.2.1.1.1 Fire Separation 5 Feet or Less, 1406.2.1.1.2 Fire Separation Greater Than 5 Feet, Section 1407 Metal Composite Materials (MCM), 1407.3 Architectural Trim and Embellishments, 1407.10 Type I, II, III and IV Construction, 1407.10.1 Surface-Burning Characteristics, 1407.11.1 Installations Up to 40 Feet in Height, 1407.11.1.1 Fire Separation Distance of 5 Feet or Less, 1407.11.1.2 Fire Separation Distance Greater Than 5 Feet, 1407.11.2 Installations Up to 50 Feet in Height, 1407.11.3 Installations Up to 75 Feet in Height (Option 1), 1407.11.3.2 Nonfire-Resistance-Rated Exterior Walls, 1407.11.3.4 Area Limitation and Separation, 1407.11.3.5 Automatic Sprinkler System Increases, 1407.11.4 Installations Up to 75 Feet in Height (Option 2), 1407.11.4.1 Minimum Fire Separation Distance, Section 1408 Exterior Insulation and Finish Systems (EIFS), Section 1409 High-Pressure Decorative Exterior-Grade Compact Laminates (HPL), 1409.3 Architectural Trim and Embellishments, 1409.10 Type I, II, III and IV Construction, 1409.10.1 Surface-Burning Characteristics, 1409.11.1 Installations Up to 40 Feet in Height, 1409.11.1.1 Fire Separation Distance of 5 Feet or Less, 1409.11.1.2 Fire Separation Distance Greater Than 5 Feet, 1409.11.2 Installations Up to 50 Feet in Height, EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS), EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS) WITH DRAINAGE, HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATE (HPL), HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATE (HPL) SYSTEM, Exterior insulation and finish systems (EIFS), exterior insulation and finish systems (EIFS) with drainage, exterior insulation and finish systems (EIFS), High-Pressure Decorative Exterior-Grade Compact Laminates, a. Spray foam with a minimum density of 2 lbs/ft, Compliance with the requirements for a means of drainage, and the requirements of Sections, Wood siding of thicknesses less than 0.5 inch shall be placed over sheathing that conforms to. That's because a cook needs to be able to turn around, bend over to reach items out of lower cabinets, and pull hot pans of chocolate chip cookies out of the oven. The maximum distance to the vent is 6 feet under the IRC; 3 feet 6 inches under the UPC. Habitable rooms shall have an area of no less than 70 s.f. The following documents represent a summary of the BCC amendments: Building Code 2012 (Chapters 1-15, 34-end) NC Amendments, Building Code 2012 (Chapters 16-33) NC Amendments, Residential Code Townhouse Sprinkler Amendment, 2012 NC Residential Code, Part 4 Energy Conservation (Adopted 12/14/2010), 2012 NC Energy Conservation Code (Adopted 12/14/2010), Energy Conservation Code HVAC System Verification Amendment, 20122017 Accumulative Supplement to the 2012 NC Codes (Effective 1/1/2017), 20122015 Approved Cumulative Amendments (Effective 1/1/2015), 20142016 Approved Cumulative Amendments (Effective 1/1/2016), 20152017 Approved Cumulative Amendments (Effective 1/1/2017), 20162018 Approved Cumulative Amendments (Effective 1/1/2018), R602.10 Code and Commentary for 2012 NC Residential Code - final 03-06-13.pdf, 2012 NCECC, 2012 NCRC, Duct Leakage to the Outside, 2012 NC Residential Code, Chapters 5 & 8, Southern Pine Span Tables, 2012 NC Building Code, Chapter 23, Southern Pine Span Tables. The North Carolina Building Codes are promulgated by the North Carolina Building Code Council (BCC) and are interpreted and enforced by the Engineering and Codes Section. Raleigh NC 27699-1201, Contact OSFMEmployee DirectoryCareers at OSFMCalendar, An official website of the State of North Carolina. This required workspace shall not be designated for storage. I encourage you to speak to an experienced interior designer to truly optimize your new kitchen layout (and ensure you don't run afoul of your local building code). For all but the most minor cosmetic building projects, city inspectors will check to make sure that building codes were followed. The 2008 Electrical Code was effective from June 1, 2008 through July 3, 2011. Aluminum siding shall conform to the requirements of AAMA 1402. At least a 15-inch landing area not more than 48 inches across from the oven is acceptable if the appliance does not open into a walkway. A window that opens and lets in the breeze could blow out the gas flame on your range and create a different sort of safety hazard. 3 in. Ducts for range hoods must include a damper and outdoor termination. If your current kitchen layout is violating any of these recommendations, you'll probably already be aware of the negative consequences poor kitchen design can have. An oven needs a bit of countertop on either side on which a hot pan can be placed. A list of currently approved termiticides. Cutting a hole in the door to install a pet-door flap voids the 20-minute rating. Stud spacing shall be per TABLE 1, shall have a pressure treated bottom plate and can have a single or double top plate. Surface mounted incandescent fixtures - 12" minimum. Storage areas that are more than 84 above the floor must be counted in the miscellaneous category. All editions of the NEC can be accessed through the NFPA website at NEC Access (Note: NFPA requires an user account be created prior to viewing the Codes) Go to the State Electrical Division Webpage